- Features & Benefits
- Main applications
- Technical Specifications
- Technical Data
- Approvals & Certifications
- Downloads
- ProScatter™ Backscatter sensor technology with superior minimum detection <1mg/m3
- Certified to 15 mg/m3 for processes with low typical emission limits
- Manual and remote Zero and Span (reference) checks available to ensure optimal instrument performance and to comply with EN 13284/QAL1
- Automatic Functionality Check – fully interrogates the optical system
- Purge Flow Fail Sensor option with inbuilt automatic optical shield activation
- Flue Gas Blocker option to protect Plant Engineers from harmful flue gases during maintenance
- Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration
- Non-condensing / dry flue gases
- Typical Applications:
- Incineration
- Metals (eg Steel/Aluminium)
- Minerals (eg Cement/Gypsum)
- Chemicals (eg TiO2 / Coating Powder)
- Power Generation Plant (eg Coal/Biomass)
Technical Specifications | |
---|---|
Measured parameters | Dust |
Technology | ProScatter™ Backscatter |
Measurement/Monitoring capability | <0 – 500 mg/m3* |
Stack/Duct diameter suitability | up to 10m |
Flue gas temperature | up to 400°C |
Baghouse | YES |
Cartridge Filter | YES |
Ceramic Filter | / |
Coalescent Filter | / |
Cyclone | YES |
Electrostatic Precipitator (ESP) | YES |
Wet Electrostatic Precipitator (WESP) | / |
Wet Scrubber | / |
Sensor variants | Stainless Steel |
QA checks | YES |
*Application dependant
Technical data | |
---|---|
Measurement capability | <0 – 500 mg/m3 |
Sensor Variants | 316 Stainless Steel |
Stack Temperature Ranges | -20°C – 250°C up to 400°C option |
Functionality and QA Checks | Automatic zero and span |
Data Output | RS485 (Modbus) output to Controller |
Air Purge | option |
Enclosure Protection Rating | IP65 |
- MCERTs certified to EN15267-3
- QAL1 as defined by EN14181
- QAL3 compliance to EN14181