e-Series Sulfur dioxides Analyzer SO₂

AF22e

UV Fluorescence gas monitor offering excellent performances for the monitoring of SO2 in the range 0-10 ppm or 0-1 ppm. Option: H2S / TRS monitoring

Eco-designed, reference air quality monitor, QAL1 certified by the TÜV, US-EPA approved. Utilizes the standard method for the measurement of sulfur dioxides (EN 14212). With its ultra low power consumption & 24 V supply (option), the AF22e is the sole SO2 monitor on the market able to measure without being connected to the power grid.

  • Superior metrological performances for SO2 measurements in ranges 0-10 ppm or 0-1 ppm
  • Innovative design of the optical module for excellent sensitivity and signal stability
  • Real-time calibration graph, animated synoptic, auto-diagnostic, control and maintenance data screens can be displayed while the instrument is operating
  • Embedded Communication Protocol for XR® Software with automatic recognition and configuration
  • Able to withstand temperatures up to 45-50 °C without air conditioning
  • Special architecture means that no additional pump is necessary in case of permeation bench (in option)
  • Automatic recognition of plugged electronic boards or optional devices: plug & play principle
  • Smart, connected instrument with embedded web server for the easiest, full remote control and operation of the analyzer from any PC, tablet or smartphone (configuration, calibration, test, diagnostic parameters…)
  • Integrated web-server with full remote emulation of the analyzer through the ENVEA Connect free app
  • Continuous indoor and outdoor air quality monitoring
  • Stationary and mobile AQMS laboratories
  • Industrial fence-line monitoring
  • Continuous emissions monitoring (CEM) by dilution
  • Laboratory & field studies on SO2 / H2S / TRS effects…
  • Background (urban or suburban) Rural, Traffic, Kerbside measurement campaigns and monitoring studies
Technical specifications
Measured parameter SO2
Technology UV Fluorescence
US-EPA Approval / QAL 1 Certification YES
Measurement ranges 0-1 ppm or 0-10 ppm user-defined
Measurement units ppb, ppm, µg/m3 user-defined
Lower Detectable Limit (2σ) < 0.4 ppb
Noise (σ) < 0.2 ppb
Zero drift < 1 ppb / 24h
Span drift < 0.5% / 7 days
Linearity ± 1%
Sample flow rate 20L/h
Sample pump internal
Temperature range 0°C to +40°C
Data storage 1 year
Included I/O 1LAN/3USB/WIFI/2DRY
Weight (Kg) 9,8
Dimensions mm (LxWxH) 483 x 545 x 133
Chassis 19″ Rack, 3U
Power supply 115 V, 60 Hz – 230 V, 50 Hz
24 V optional
Pressure and temperature compensation YES
    MAIN OPTIONS:

  • Analyzer without screen for reduced environmental impact
  • Additional parameters: SO2, H2S, CH2SH, COS, CS2, (CH2)2S…
  • 24 V Power supply PLUS extended temperature range 0-50°C
  • Built-in permeation bench with SO2 tube (additional pump not required)
  • Internal converter for H2S monitoring (range 0-1000 ppb)
  • CTRS External module, to be used in combination with the AF22e SO2 analyzer for the continuous measurement of TRS compounds or cyclic measurement SO2/TRS
    COMPLIANCE WITH:

  • 2008/50/EC, EN 14212, EN 15267, 40 CFR PART 53 SUB B and SUB C
  • QAL 1 certified by the TÜV to N° 0000051690
  • U.S. EPA approved as compliant with EQSA-0802-149
    ENVEA monitoring solutions are European QAL 1 certified and in compliance with the latest international regulations & standards.
    They are also approved and certified by various laboratories and organizations around the world such as: US EPA, TÜV, GOST, CEN, JQA, CNEMC, JMOE, KTL, CNSA, LCSQA…

Cases Studies