e-Series Nitrogen Oxides Analyzer NO, NOx & NO₂

AC32e dilution

CLD based gas monitor offering superior performances for the measurement of NO, NO2 and Nox in the range 0-4000 µg/m3 based on 100/200 Dilution Rate

Eco-designed, reference air quality monitor, based on the chemiluminescence technology, the standard method for the measurement of nitrogen oxides (EN 14211). QAL1 certified by the TÜV, US-EPA approved. With its ultra low power consumption & 24 V supply (option), the AC32e is the sole NOx analyzer on the market able to measure without being connected to the power grid.

  • Excellent sensitivity & metrological performances for NO, NO2 and NOx measurements
  • Real-time calibration graph, animated synoptic, auto-diagnostic, control and maintenance data screens can be displayed while the instrument is operating
  • Service assistance inside: detects early signs of trouble, allows predictive maintenance, identifies the needed service and guides service operations step by step: increased productivity on site, reduced downtime, more efficiency, less training…
  • Embedded Communication Protocol for XR® Software with automatic recognition & configuration
  • Able to withstand temperatures up to 45-50 °C without air conditioning
  • Smart, connected instrument with embedded web server for the easiest, full remote control and operation of the analyzer from any PC, tablet or smartphone (configuration, calibration, test, diagnostic parameters…)
  • Continuous emissions monitoring (CEM) by dilution
  • Stationary and mobile AQMS laboratories
  • Industrial fence-line monitoring
  • Continuous indoor and outdoor air quality monitoring
  • Background (urban or suburban), Rural, Traffic, Kerbside measurement campaigns and monitoring studies
  • Laboratory and field studies on pollution effects
Measurable parameters
Pollutant Range
NO 0-150 / 3000
NO2 0-200 / 4000
NOx 0-200 / 4000
Lowest / Highest available ranges expressed in mg/m3 (may vary with your site conditions to be indicated on the Site Survey Form)
(*) Min/Max based on 100/200 Dilution Rate (other ranges & dilution rates available upon request)
Technical specifications
Sampling technology Dilution
Sample transfert non heated polytube
back flush function YES
span injection YES
Built-In O2 option NO
Serial link communication Optional
Other Communication Ethernet
Analogue OUTPUTS Optional
Analogue INPUTS Optional
Dimensions (mm) 19” rack: 483 x 545 x 133 mm (D x W x H)
    MAIN OPTIONS:

  • 7’’ TFT color touch screen
  • WiFi module (in standard with the no-screen version)
  • RS232 or RS485 serial interface (via USB port)
  • External module for NH3 measurement (0-1000 ppb)
  • Built-in permeation bench with NO2 tube
  • Sample dryer
  • External opto-isolated I/O interface with:
    4 independent analog inputs
    4 independent analog outputs
    4 remote control inputs
    6 dry contacts outputs
Our monitoring solutions are European QAL 1 certified and in compliance with the latest international regulations & standards.
They are also approved and certified by various laboratories and organizations around the world such as: US EPA, TÜV, GOST, CEN, JQA, CNEMC, JMOE, KTL, CNSA, LCSQA…

    COMPLIANCE WITH:

  • ISO 7996, EN 14211 (2012), EN 15267 (2009), 40 cfr part 53 & part 58
  • QAL 1 certified by the TÜV to N° 0000053805
  • U.S. EPA approved as compliant with RFNA-0118-249