Particulate CEM for wet gas streams

QAL 182 WS

QAL1 approved ProScatter™ particulate CEM for the extractive sampling and measurement of particulate in saturated wet gas streams

Continuous Particulate Monitoring for saturated wet stack applications typically found after wet scrubbers, wet electrostatic precipitators and wet flue gas desulphurisation plant

QAL1 certified against EN 15267-3 to meet EN 14181 and other International standards

  • Extractive sampling system configurable for fixed velocity or isokinetic variable flow rate sampling
  • Continuous Particulate Monitoring for saturated wet stack applications typically found after wet FGDs or filtration systems that produce a wet/condensing flue gas (wet ESPs/scrubbers)
  • Meets QAL1 and other International standards
  • Heated sample lines to maintain sample temperature and prevent the formation of condensation
  • Forward Scatter measurement technique with automatic zero and span (upscale) checks
  • Easy to use intuitive multi-lingual menu with large display for improved user interface complete with on-board diagnostics and multiple analogue and digital communication outputs
  • Small sample chamber and use of advanced polymers – prevents particulate adhesion, condensation and crystal formation. Reduced maintenance for the end user
Stacks with saturated wet flue gas, typically after wet flue gas desulphurisation plant, wet collectors, etc
Typical Applications:
  • Power Generation Plant eg Coal/Biomass
  • Incineration
  • Metals eg Steel/Aluminium
  • Minerals eg Cement/Gypsum
  • Chemicals eg Detergent / Carbon Black
  • Fertiliser
  • Pulp and Paper
Technical Specifications
Measured parameters Dust
Technology Extractive ProScatter™ Forward Scatter
Measurement/Monitoring capability 0-500 mg/m3*
Stack/Duct diameter suitability up to 15m
Flue gas temperature up to 200°C
Baghouse /
Cartridge Filter /
Ceramic Filter /
Coalescent Filter /
Cyclone /
Electrostatic Precipitator (ESP) /
Wet Electrostatic Precipitator (WESP) YES
Wet Scrubber YES
Sensor variants PVDF corrosion resistant
Stainless Steel
Hastelloy®
QA checks YES
*Application dependant
Technical data
Measurement capability 0 – 500 mg/m3 (for higher concentrations, please consult ENVEA)
Detection Limit < 0.1 mg/m3
Probe Variants Probe lengths 600mm, 1200mm (other lengths available on request)
– PVDF (standard) corrosion resistant
– Stainless Steel: non-corrosive stacks
– Hastelloy® corrosion resistant
Stack Temperature Ranges up to 200°C
Functionality and QA Checks Automatic self-checks (zero and span), QA data logging
Outputs RS485 (Modbus) RS232 (Modbus) Ethernet
  • TÜV (UBA) certified to EN15267-3
  • QAL1 as defined by EN14181
  • QAL3 compliance to EN14181