Filter Performance Monitors - Condition Based Monitoring
The LEAK LOCATE 662 is a digitally networked, multi-compartment baghouse monitoring system providing remote observation of the condition of bag and cartridge filters. Condition Monitoring
Controller based filter dust leak monitor for filter emissions monitoring after bag houses, cartridge filters, cyclones etc.
- Features & Benefits
- Main applications
- Technical Specifications
- Technical Data
- Approvals & Certifications
- Downloads
- Reliable monitoring of leaking and broken bags in dust collectors
- Sensor configured remotely via controller
- Manual sensor Drift Checks (zero and span)
- Probe Check (Insulator Short-Circuit Check) option for improved data integrity
- Digital display and optional graphical display to view live data and monitor bag cleaning cycle
- Reduces filter maintenance intervals, process down-time and filter costs
- Particulate monitoring in stacks after bag filters, cartridge filters, cyclones
- Variable velocities within range 4-30m/s (typical bagfilter velocity ranges), constant velocity required outside this range
- Typical Applications:
- Incineration
- Metals (eg Steel/Aluminium)
- Minerals (eg Cement/Gypsum)
- Chemicals (eg Detergent / Ti02)
- Food (eg Milk Powder / Tobacco)
- Power (eg Boilers/Biomass)
Technical Specifications | |
---|---|
Measured parameters | Dust |
Technology | ElectroDynamic™ Advanced Probe Electrification |
Measurement/Monitoring capability | 0-500 mg/m3* |
Stack/Duct diameter suitability | up to 4m |
Flue gas temperature | up to 250°C |
Baghouse | YES |
Cartridge Filter | YES |
Ceramic Filter | / |
Coalescent Filter | / |
Cyclone | / |
Electrostatic Precipitator (ESP) | / |
Wet Electrostatic Precipitator (WESP) | / |
Wet Scrubber | / |
Sensor variants | Stainless Steel Fully insulated PTFE coated |
QA checks | YES |
*Application dependant
Technical Data | |
---|---|
Measurement capability | 0-500 mg/m3 |
Sensor Variants | 316 Stainless Steel (standard) / Fully insulated PTFE coated (option) |
Stack Temperature Ranges | 0-250°C standard |
Functionality and QA Checks | Drift check (zero and span), Probe short circuit check option |
Inputs | 4x Digital inputs 2x 4-20mA inputs |
Outputs | Optional RS232, RS485 (Modbus) 2 x Digital Alarm and 4/20mA |
Display | Two Line Digital display and Bar graph Large Graphical Bag Pulse Display (option) |
Air Purge | Option |
- US EPA MACT Compliant BLD
- Ex Zone 22