Heated Flame Ionization Detection (FID) Analyzer
One of the sole QAL 1 certified FID analyzers on the market, also available in a transportable version for the measurement of: THC or simultaneous THC, nmHC & CH4
Utilizes Flame Ionization Detection (FID), the most sensitive and widely used technology for the measurement of: Total hydrocarbons (THC) / Non-methanic Hydrocarbons (NmHC) / Methane (CH4)
• Available in 2 versions:
GRAPHITE 52M-S : THC monitoring
GRAPHITE 52M-D : THC, NmVOC & CH4 simultaneous monitoring
- All elements in contact with the sample from its extraction to the analysis are heated
- Adapted for checking the efficiency of a treatment process (upstream / downstream)
- Integrated zero air generator with catalyzer
- Up to 191°C heated detector for high concentration HC measurement
- Fuel used: mixture of H2 & He (QAL1) or pure H2 (optional)
- Fast response time, perfectly suited for wet and corrosive sample measurements
- High accuracy, sensitivity and stability
- User adjustable response time and averaging time
- Real time calibration graph
- High efficiency long-life catalyst
- Internal zero and air scrubber
- Graphic LCD Display with interactive menu driven software and enhanced speed display
- AK protocol communication (RS232 / RJ45), built-in Ethernet TCP/IP connection, USB port for remote control and serial interface RS 232
- Complies with EN 12619 & EN 13 526 standards for emissions monitoring and CFR 40 1065 (US EPA) for engine emission testing of hydrocarbons
- Compliance & process monitoring
- Engine exhaust gas & automotive emission testing
- Stack Monitoring
- Monitoring effluent of volatile organic compound (VOC) reduction equipment for:
– Environmental compliance
– Efficiency control of incinerators (Thermal or catalytic)
- Carbon absorbers
- Monitoring of catalytic converters
- Combustion and diesel engine efficiency
- Scrubbers
Measurable parameters | ||
---|---|---|
Pollutant | Range (ppm) |
|
CH4 | 0-10 / 10000 | |
THC | 0-10 / 10000 |
Technical Specifications | |
---|---|
QAL1 to EN 15267-3 certified | YES |
US EPA compliance | YES |
Sampling technology | Hot/Wet Extraction |
Sample transfert | 180°C heated sampling line |
back flush function | YES |
span injection | YES on analyser or at sample point |
Built-In O2 option | NO |
Serial link communication | RS232 / RS422 |
Other Communication | Ethernet |
Analogue OUTPUTS | Optional |
Analogue INPUTS | NO |
Dimensions (mm) | 19” rack: 483 x 470 x 177 (L x W x H) |
- QAL 1 certified by the TÜV and the MCERTs according to EN 15267-3 and the EN 14181
Sira MC 060082/11 - U.S. EPA approved as compliant with CFR 40-1065
- Compliance with EU Regulations: IED (WID), LCPD, MCP directive,
- Compliance with EN 12619 & EN 13526, US EPA (40 CFR 60 & 75, CFR 40-1065)