Multi-Gas IR-GFC analyzer
Standard Reference CLD method for low & ultra low NOx measurement, IR-GFC for CO, CO2, SO2, N2O, Nox, HF, HCl, TOC and O2 in a single analyzer
Fast and simultaneous measurements of up to 10 gases, available in 2 versions:
– NOx (CLD) and O2 (Paramagnetic) in 19’’ Rack or Tight box for low and ultra-low NOx monitoring
– CO, CO2, SO2, HCl, HF, TOC, N2O (IR) + NOx (CLD) + O2 (Paramagnetic) in Tight box
Lowest QAL 1 certified range for NOx/NO & NO2 of the CEMS market: 20 mg/Nm3
- Features & Benefits
- Main applications
- Technical Specifications
- Technical Data
- Approvals & Certifications
- Downloads
- Over 4000 installations worldwide, covering many applications and industries
- Unheated sample line thanks to the permeation drying technology used
- Intrinsic security with on-board residual H2O measurements
- On-board oxygen measure for environmental reporting
- Interactive menu-driven software with real time graphic display for ease of operation
- Highly accurate, excellent stability with automatic optical stability check
- Automatic CO2 and cross interference correction
- Built-in data logger for 7 additional parameters (flow, pressure, temperature or any other analogue input)
- Compatible with various drying technologies such as a SEC sampling system or a high performance gas cooler
- Cogeneration, Gas Turbines
- Industrial Boilers
- Furnaces
- Power & Combustion
Measurable parameters | |||
---|---|---|---|
Pollutant | Range | ||
HCI | 0-15 / 5000 | ||
HF | 0-25 / 300 | ||
NO | 0-20 / 2000 | ||
NO2 | 0-20 / 2000 | ||
N2O | 0-20 / 2000 | ||
NOx | 0-20 / 2000 | ||
SO2 | 0-75 / 5000 | ||
CO | 0-75 / 10000 | ||
CH4 | 0-10 / 1000 | ||
THC | 0-50 / 5000 | ||
CO2(%) | 0-10 / 100 or 0-20 | ||
O2(%) | 0-10 / 25 |
Technical Specifications | |
---|---|
QAL1 to EN 15267-3 certified | YES |
US EPA compliance | YES |
Sampling technology | Cold/Dry Extraction |
Sample transfert | non heated polytube |
back flush function | YES |
span injection | YES on analyser or at sample point |
Built-In O2 option | YES |
Serial link communication | RS232 / RS422 |
Other Communication | Ethernet |
Analogue OUTPUTS | Optional |
Analogue INPUTS | YES (x 4) |
Dimensions (mm) | • Tight box: 200 x 600 x 600 (D x W x H) • 19” rack: 490 x 483 x 177 (D x W x H) |
- Complete system would normally comprise of:
- Sample extraction and conditioning probe (with integrated temperature, pressure and flow measurement)
- Cold sample lines
- Calibration module
- Instrument air drying module
- Acquisition and data management system (DAHS) may complement the system
- COMPLIANCE WITH LCPD AND WID APPLICATIONS
- QAL 1 certified by the MCERTs to EN 15267-3
- QAL3 compliance as defined by EN 14181
- U.S. EPA approved as compliant with 40 CFR 60 ET 75