- Features & Benefits
- Main applications
- Technical Specifications
- Technical Data
- Approvals & Certifications
- Downloads
- Reliable monitoring of leaking and broken bags in dust collectors
- Manual sensor Drift Checks (zero and span)
- Probe Check (Insulator Short-Circuit Check) option for improved data integrity
- Reduces filter maintenance intervals, process down-time and filter costs
- Typical Applications:
- Incineraton
- Metals (eg Steel/Aluminium)
- Minerals (eg Cement/Gypsum)
- Chemicals (eg Detergents / Ti02)
- Boilers
- Stacks after bag filters, cartridge filters, cyclones
- Variable velocities within range 4-30m/s (typical bagfilter velocity ranges), constant velocity required outside this range
- After process driers
- Non-condensing / dry flue gases
Technical Specifications | |
---|---|
Measured parameters | Dust |
Technology | ElectroDynamic™ Advanced Probe Electrification |
Measurement/Monitoring capability | 0-500 mg/m3* |
Stack/Duct diameter suitability | up to 6m |
Flue gas temperature | up to 400°C |
Baghouse | YES |
Cartridge Filter | YES |
Ceramic Filter | / |
Coalescent Filter | YES |
Cyclone | YES |
Electrostatic Precipitator (ESP) | / |
Wet Electrostatic Precipitator (WESP) | / |
Wet Scrubber | / |
Sensor variants | Stainless Steel Fully insulated PTFE coated |
QA checks | YES |
*Application dependant
Technical Data | |
---|---|
Measurement capability | 0-500 mg/m3 |
Sensor Variants | 316 Stainless Steel (standard) / Fully insulated PTFE coated (option) |
Stack Temperature Ranges | 0-250°C standard, up to 400°C option |
Functionality and QA Checks | Drift check (zero and span), Probe short circuit check option |
Outputs | Optional RS232, RS485 (Modbus) 2 x Digital Alarm and 4/20mA |
Air Purge | Option |
- US EPA MACT Compliant BLD
- Ex Zone 20