Velocity measurement, material transport

SpeedFlow 2.0-Pipe

Velocity measurement in full cross-section version. Continuous velocity measurement in tube version for careful material transport. Measures in full cross-section.

  • Continuous speed measurement of solids (powder, granules, dust ) in metal pipes
  • Measurement directly in the conveying stream / entrained flow
  • Measurement is completely independent of material
  • Sensor is made accordingly to the existing pipe diameter
  • Measurement without product contact
  • Plastic industry
  • Tobacco
  • Food
Technical Specifications
Material to measure Dust, powders or granulates
Working principle Correlation
Process pressure Max. 100 mbar
Process temperature Max. +45°C
Mounting Flare connection
Type of Conveying Pneumatic leanphase
Velocity range 1…35m/s
Pipe diameter Max. 350mm
ATEX rating None
Output 4…20mA, Modbus, Profibus
  • Materials: Granules, Powder and dust
  • No calibration (Plug & Play)
  • Without build-in components into the flow
  • Range of application: starts with material speed as low as 0.75 m/s
Sensor Technical Data
Innerdiameter DN: 80, 100, 150, 200, 250, 350
(other sizes on request)
Material inner pipe PMMA
Mechanical connection Flare connection
Protection category IP 54
Max. pressure 100 mbar
Velocity range 1…35 m/s/td>
Temperature inside the pipe 0…+50 °C
Temperatur outside the pipe 0…+45 °C
Power supply 24 V DC
Weight Depend on diameter
Measuring accuracy ± 1 %
(in the calibrated measuring range)
Transmitter Technical Data
Transmitter (DIN Rail) Transmitter (field housing)
Power supply 24 V DC ±10 % 110 / 230 V AC 50 Hz
(optional 24 V DC)
Power consumption 20 W / 24 VA
Protection type IP 40 to EN 60 529 IP 65 to EN 60 529/10.91
Ambient operating temperature -10 … +45 °C
Dimensions (W x H x D) 23 x 90 x 118 mm 258 x 237 x 174 mm
Weight Approx. 172 g Approx. 2.5 kg
Connection terminals cable
cross-section
0.2-2.5 mm2 [AWG 24-14]
Current output 1 x 4 … 20 mA (0 … 20 mA),
load < 500 Ω
3 x 4 … 20 mA (0 … 20 mA),
load < 500 Ω
Interface RS 485 (ModBus RTU) / USB
Pulse output Open collector – max. 30 V, 20 mA
Relay contact Max. rated load:
250 V AC
Max. peak current:
6 A
Max. rated load 230 V AC:
250 VA
Max. breaking capacity DC1:
3/110/220 V: 3/0.35/0.2 A
Min. switching load:
500 mW (10 V / 5 mA)
Data backup Flash memory
For the assembly of the sensor, the installation location is specified in accordance with the conveyed inlet and outlet paths. At the specified installation location the sensor is installed in the extisting pipeline via a standard flare connection. The distance between sensor and analysis unit can be a maximum of 300 m.