Dust measurement after filters
Provides continuous measurement values for dust concentration as a trend signal or absolute values.
The ProSens has been specially developed to carry out reliable dust measurement on clean sides after filters.
The measuring device provides measurement values for dust concentration, either as a trend signal or as absolute values (after calibration) for emission measurement.
Particles in the gas flow
From 0.1 mg/m3
Standard: 150 °C, optional: max. 500 °C
Max. 2 bar (Optional: up to 25 bar)
Min. 4 m/sec
95 % rel. hum. or less (non-condensing)
Electrodynamic technology
-20…+ 60 °C
Material: stainless steel; length: 500 / 1000 mm
Aluminium
IP 66; ATEX: cat. 1/2 GD
Connection room DIN M 20
Relay with switching contact, Max. 125 V/AC, 2 A, Not for EX-devices Cat. 1 and 2
Approx. 1.5 kg
24 V DC ±10 %, 20 W / 24 VA
IP 40 to EN 60 529
-10 … +45 °C
23 x 90 x 118 mm
Approx. 172 g/td>
DIN 60715 TH35
0.2-2.5 mm2 [AWG 24-14]/td>nn
1 x 4 … 20 mA (0 … 20 mA), load < 500 Ω
ModBus RTU (RS 485) / USB/td>
Open collector – max. 30 V, 20 mA
Max. rated load: 250 V AC, Max. peak current: 6 A, Max. rated load 230 V, AC: 250 VA, Max. breaking capacity DC1: 3/110/220 V: 3/0.35/0.2 A, Min. switching load: 500 mW (10 V / 5 mA)/td>