QAL1 approved ProScatter™ particulate CEM for the extractive sampling and measurement of particulate in saturated wet gas streams.
Continuous Particulate Monitoring for saturated wet stack applications typically found after wet scrubbers, wet electrostatic precipitators and wet flue gas desulphurisation plant.
QAL1 certified against EN 15267-3 to meet EN 14181 and other International standards
Dust
Extractive ProScatter™ Forward Scatter
0-500 mg/m3*
up to 15m
up to 200°C
/
/
/
/
/
/
YES
YES
PVDF corrosion resistant / Stainless Steel / Hastelloy®
YES
0 – 500 mg/m3 (for higher concentrations, please consult ENVEA)
< 0.1 mg/m3
Probe lengths 600mm, 1200mm (other lengths available on request) – PVDF (standard) corrosion resistant – Stainless Steel: non-corrosive stacks – Hastelloy® corrosion resistant
up to 200°C
Automatic self-checks (zero and span), QA data logging
RS485 (Modbus) RS232 (Modbus) Ethernet